model:H3-C3-2T-3B
brand:ZEMIC
· Nickel plated alloy steel IP67 “S”type load cell
· Tension and compression applications
· Suitable for hanging, hopper and other weighing devices
· Also available in imperial capacities and dimensions
1、SPECIFICATION
Accuracy class |
| OIML R60 C3 | OIML R60 C4 | C3 |
Output sensitivity ( = FS ) | mV/V | 2.0±0.004( Metric ) 3.0±0.008( Imperial ) |
Maximum capacity ( E max ) | t | 0.025/0.05/0.1/0.15/0.2/0.25/0.3/0.5/0.6/0.75/1/1.5/2/2.5/3/5/7.5/10/15/20/30 |
lb | 100/150/200/250/300/500/750/1K/1.5K/2K/2.5K/3K/5K/10K/15K/20K |
Maximum number of load cell intervals ( nLC ) |
| 3000 | 4000 | 3000 |
Ratio of minimum LC verification interval Y = E max / vmin |
| 10000 | 20000 | 10000 |
Combined error | %FS | ±0.020 | ± 0.018 | ±0.020 |
Minimum dead load | kg | 0 |
Safe overload | %FS | 150 |
Ultimate overload | %FS | 300 |
Zero balance | %FS | ±1.5( Metric ) ±1.0( Imperial ) |
Excitation, recommended voltage | V | 5 ~ 12( DC ) |
Excitation maximum | V | 18( DC ) |
Input resistance | Ω | 350 ± 3.5 |
Output resistance | Ω | 351 ± 2.0 |
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) |
Compensated temperature | ℃ | -10 ~+40 |
Operating temperature | ℃ | -35 ~ +65 |
Storage temperature | ℃ | -40 ~ +70 |
Element material |
| Nickel plated alloy steel |
Ingress protection (according to EN 60529) |
| IP67 |
Recommended torque on fixation | N.m | M8:25 M10: 50 M12:75 M20:450 M33:750 M42:1450 |
ATEX classification (optional) |
| II1G Ex ia IIC T4 | II1D Ex iaD 20 T73℃ | II3G Ex nL IIC T4 |
2、DIMENSIONS mm(inch)

Dimension Capacity | H | L | W1 | M | H1 |
25kg ~ 50kg | 76.2 (3.0) | 50.8 (2.0) | 12.7 (0.5) | M8 | 15.7 (0.62) |
0.1t , 0.15t | 76.2 (3.0) | 50.8 (2.0) | 19 (0.75) | M10×1.5 | 15.3 (0.60) |
0.2t ~ 0.75t | 76.2 (3.0) | 50.8 (2.0) | 19 (0.75) | M12×1.75 | 15.1 (0.59)~12.5 (0.48) |
1 , 1.5t | 76.2 (3.0) | 50.8 (2.0) | 25.4 (1.0) | M12×1.75 | 12.6 (0.50), 11.7 (0.46) |
2t ~ 5t | 101.6 (4.0) | 76.2 (3.0) | 25.4 (1.0) | M20×1.5 | 20 (0.79) |
7.5t , 10t | 175 (8.89) | 125 (4.92) | 50 (1.97) | M33×3 | 41 (1.61), 39.5 (1.56) |
15t , 20t | 200 (7.87) | 160 (6.3) | 60 (2.36) | M42×3 | 51 (2.01) |
30t | 230 (9.06) | 190 (7.48) | 80 (3.15) | M42×3 | 57.5 (2.26) |
3、WIRING

· Shielded, 4 conductor cable.
· Cable diameter: Φ5mm
· Standard cable length for 25kg - 1.5t: 3m and for 2t - 30t: 6m.
· Shield not connected to element.
Here is the detailed information of the H3-C3-2T-3B load cell. As a home of imported sensors, Shenzhen Xiandai Haofang Instrument and Meter Technology Co., Ltd. has perfect technical services and pre - sales and after - sales support. If necessary, please contact us. Mobile/WeChat: 13392863941.